1N=0.102kgf=0.2248lbs.1mm=0.03937inchⅢ-46Mountingprocedureswhentrackrailsarebutt-jointedWhenmultipletrackrailsarebutt-jointed,itisnecessarytospecifyspecialspecificationbuttedtrackrails(non-interchangeablespecification,supplementalcode"/A")orbutt-jointingtrackrails(interchangeablespecification,supplementalcode"/T").Butt-jointingtrackrailshaveabutt-jointingmarkonthetrackrailendsurfaceasindicatedinFig.42.Typicalmethodtobutt-jointthetrackrailsisasfollows.❶Alignthebutt-jointingmarkonthetrackrailendsurfaceandtemporarilyfixit.Sincebutt-jointingtrackrailsareinterchangeable,nobutt-jointingpositionisspecified.❷Correctlyalignthereferencemountingsurfaceofthetrackrailwiththatofthebedinorder.Atthispoint,useasmalltypeviseortheliketostickthereferencemountingsurfacesofthebedandtrackrailtogethersoastoeliminateanystepatthejointpartofthetrackrail.(SeeFig.43)Fig.43Methodtobutt-jointtrackrailsFig.42Butt-jointingmark4-A14-A14-B14-B14-A4-A4-B4-B4-A24-A24-B24-B2GuidetoMountingVideosInstructionalvideosaboutthemountingmethodsforlinearmotionrollingguidesareavailableontheIKOwebsite.Pleaseutilizethemwhennecessary.https://www.ikont.co.jp/eg/


<< | < | > | >>